DC systems and batteries — dedicated protection and monitoring

DC systems in substations (110/220 V auxiliary supply), battery energy storage installations (BESS), DC traction systems and hybrid vessel power architectures need a different protection device family than AC systems. Direct DC current and voltage measurement, shunt and transducer inputs, polarity-aware fault logic and an interface to the battery management system (BMS) define the application.

SYMAP® is not a BMS replacement. SYMAP® Y-BAT and Y-DC variants provide DC-side protection (overcurrent, earth-fault, undervoltage, insulation, breaker control) and a signal and communication interface to the BMS over Modbus or IEC 61850.

DC system protection

Typical DC applications

Substation auxiliary DC

110 V or 220 V DC auxiliary supply for substations. Battery and charger monitoring, insulation supervision, automatic transfer between two charger groups.

BESS — battery storage

Grid-connected battery storage installations. DC monitoring on the battery side (Y-BAT), AC grid connection through Compact+ GC with NA protection and Grid Code logic.

Hybrid vessels

Diesel + battery + converter architectures, DC and AC bus sections, peak shaving, spinning reserve reduction. Signal interface to the BMS, not a BMS replacement.

DC traction supply

DC substations for rail and metro traction (750 V, 1500 V, 3000 V). High-speed DC fault protection, rectifier monitoring, regenerative-braking integration.

Solar plant DC side

String-level and combiner-box monitoring in utility-scale PV plants. Insulation supervision, ground-fault detection, arc-fault detection on the DC side.

HVDC interfaces

Auxiliary protection and monitoring on HVDC converter stations. Project-specific configurations with extended I/O through CMA and EBS modules.

Compact+ or classic SYMAP®?

Classic SYMAP® Y-DC / Y-BAT is the dedicated variant for DC and battery applications with DC measurement, shunt/transducer inputs and an interface to BMS and SCADA. SYMAP® Compact+ GC applies to the AC grid connection of BESS installations (NA protection, Grid Code). SYMAP® is not a BMS replacement, it provides a signal and communication interface to the BMS.

Products covering DC applications

Need detailed technical specifications?

For exact protection function coverage, settings ranges, DC measurement specifications, shunt/transducer interface, BMS communication protocols and configuration support, contact our team to receive the relevant datasheet and engineering proposal.

Request datasheet Engineering inquiry

Stucke Elektronik Balkan d.o.o.
Ustanička 168, 11050 Belgrade, Serbia · +381 11 40 49 690
© 2026 Stucke Elektronik Balkan d.o.o., All Rights Reserved