Protection for emergency power and backup systems
For data centres, SYMAP® solutions cover protection, control, metering, interlocking, communication and diagnostics of the internal power infrastructure: generator systems, MV and LV switchgear, transformer and feeder cells, section cells, UPS/ATS architecture, auxiliary supplies and critical load branches. SYMAP® products are installed in approximately 1,000 emergency power and energy backup systems worldwide, including data centres, hospitals, shopping centres, airports, stadiums and governmental buildings. SYMAP® Compact+ has DNV Cyber Secure Essential Type Approval per IEC 62443-3-3 security level 1.
SYMAP® Compact+ is considered for individual cells when protection, switchgear control, signalling, metering, local logic and communication are required in a single IED. For multiple generator sets, bus-tie logic, automatic load shedding, load prioritization and more complex backup operating modes, the corresponding SYMAP® variants are considered for Power Management and system coordination.
Note: the focus of this application is the internal power architecture of the data centre, within the facility or campus. SYMAP® is not offered as a solution for external HV connection lines or utility feeds to the site.
Note: Compact+ F1/F2/F3/F4 should not be interpreted as direct equivalents of the classic SYMAP® F/M/T/G variants. The Compact+ variant is selected according to measurement inputs, CT/VT configuration, I/O, communication and Order Code options. The classic SYMAP® series is selected according to the application and system architecture.
Which SYMAP® for this application?
For data centres, SYMAP® solutions are not limited to backup generators; they cover the internal power infrastructure of the facility: generator cells, MV/LV switchgear, bus-tie logic, ATS/UPS architecture, transformer and feeder cells, auxiliary supplies and critical load branches. For individual cells, SYMAP® Compact+ is most often considered, while for multiple generator units, Power Management, load sharing, load shedding and more complex system coordination, the corresponding SYMAP® G / ECG / BCG variants are considered. The focus of this application is within the data centre or campus, not the external HV utility feed to the site.
Installation references and market position:
Communication and monitoring features depend on the selected configuration and Order Code.
Contact our team for project-specific specifications, datasheets, configuration support, and pricing. Detailed technical data is available on request.